Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Sensors (Basel) ; 23(23)2023 Nov 29.
Artigo em Inglês | MEDLINE | ID: mdl-38067871

RESUMO

Disease diagnosis and monitoring using conventional healthcare services is typically expensive and has limited accuracy. Wearable health technology based on flexible electronics has gained tremendous attention in recent years for monitoring patient health owing to attractive features, such as lower medical costs, quick access to patient health data, ability to operate and transmit data in harsh environments, storage at room temperature, non-invasive implementation, mass scaling, etc. This technology provides an opportunity for disease pre-diagnosis and immediate therapy. Wearable sensors have opened a new area of personalized health monitoring by accurately measuring physical states and biochemical signals. Despite the progress to date in the development of wearable sensors, there are still several limitations in the accuracy of the data collected, precise disease diagnosis, and early treatment. This necessitates advances in applied materials and structures and using artificial intelligence (AI)-enabled wearable sensors to extract target signals for accurate clinical decision-making and efficient medical care. In this paper, we review two significant aspects of smart wearable sensors. First, we offer an overview of the most recent progress in improving wearable sensor performance for physical, chemical, and biosensors, focusing on materials, structural configurations, and transduction mechanisms. Next, we review the use of AI technology in combination with wearable technology for big data processing, self-learning, power-efficiency, real-time data acquisition and processing, and personalized health for an intelligent sensing platform. Finally, we present the challenges and future opportunities associated with smart wearable sensors.


Assuntos
Técnicas Biossensoriais , Dispositivos Eletrônicos Vestíveis , Humanos , Inteligência Artificial , Monitorização Fisiológica
2.
Adv Sci (Weinh) ; 10(7): e2204171, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36461733

RESUMO

Stress affects cognition, behavior, and physiology, leading to lasting physical and mental illness. The ability to detect and measure stress, however, is poor. Increased circulating cortisol during stress is mirrored by cortisol release from sweat glands, providing an opportunity to use it as an external biomarker for monitoring internal emotional state. Despite the attempts at using wearable sensors for monitoring sweat cortisol, there is a lack of reliable wearable sweat collection devices that preserve the concentration and integrity of sweat biomolecules corresponding to stress levels. Here, a flexible, self-powered, evaporation-free, bubble-free, surfactant-free, and scalable capillary microfluidic device, MicroSweat, is fabricated to reliably collect human sweat from different body locations. Cortisol levels are detected corresponding to severe stress ranging from 25 to 125 ng mL-1 averaged across multiple body regions and 100-1000 ng mL-1 from the axilla. A positive nonlinear correlation exists between cortisol concentration and stress levels quantified using the perceived stress scale (PSS). Moreover, owing to the sweat variation in response to environmental effects and physiological differences, the longitudinal and personalized profile of sweat cortisol is acquired, for the first time, for various body locations. The obtained sweat cortisol data is crucial for analyzing human stress in personalized and clinical healthcare sectors.


Assuntos
Suor , Dispositivos Eletrônicos Vestíveis , Humanos , Microfluídica , Hidrocortisona , Glândulas Sudoríparas
3.
Polymers (Basel) ; 16(1)2023 Dec 29.
Artigo em Inglês | MEDLINE | ID: mdl-38201785

RESUMO

The use of plastics in automobiles is increasing dramatically due to their advantages of low weight and cost-effectiveness. Various products can be manufactured by recycling end-of-life vehicle (ELV) plastic waste, enhancing sustainability within this sector. This study presents the development of an electromagnetic interference (EMI) shield that can be used for protecting electronic devices in vehicles by recycling waste bumpers of ethylene propylene diene monomer (EPDM) rubber from ELVs. EPDM waste was added to a unique combination of 40/60: PP/CaCO3 master batch and conductive nanofiller of carbon nanotubes using an internal melt mixing process. This nanocomposite was highly conductive, with an electrical conductivity of 5.2×10-1S·cm-1 for 5 vol% CNT in a 30 wt% EPDM/70 wt% PP/CaCO3 master batch and showed a high EMI shielding effectiveness of 30.4 dB. An ultra-low percolation threshold was achieved for the nanocomposite at 0.25 vol% CNT. Waste material in the composite improved the yield strain by about 46% and strain at break by 54% in comparison with the same composition without waste. Low cost and light-weight fabricated composite from ELV waste shows high EMI SE for application in electronic vehicles and opens a new path to convert waste to wealth.

4.
Soft Matter ; 18(39): 7537-7549, 2022 Oct 12.
Artigo em Inglês | MEDLINE | ID: mdl-36148683

RESUMO

The use of fluoroelastomer nanocomposites for flexible electronics is increasing due to their high deformability and recoverability. Often, a high amount of conductive nanofillers and crosslinking agents is required to improve their mechanical performance, which unfavorably affects the electrical percolation threshold and conductivity due to dispersion issues. Herein, we developed a unique solution mixing (SM) technique by a fine-tuned formulation to obtain well-dispersed carbon nanotubes (CNTs) in fluoroelastomer FKM for both low and high CNT concentrations (0.2 phr and 3 phr). Effective nano-network formation was confirmed by transmission electron microscopy (TEM) and oscillatory shear rheological tests. Compared to the melt mixing (MM) process, the stretchability of neat FKM improves to 503% in the SM process versus 430% in the MM process. The electrical conductivity of the SM samples percolates at significantly lower filler concentrations (i.e., 0.35 phr in SM vs. 0.45 phr in MM) with a maximum value of 7 × 10-1 S cm-1 for 3 phr. Overall, the 2 phr CNT/FKM nanocomposite fabricated by SM exceeds those of carbon-based FKM conductors reported in the literature. The enhanced electrical and mechanical properties include an electrical conductivity of 3 × 10-1 S cm-1, a strain-to-failure of 300%, and a tensile strength at break of 12 MPa. This process is a promising approach for fabricating fluoroelastomer nanocomposites of a mechanically robust and stable stretchable conductor for various wearable electronic devices.

5.
ScientificWorldJournal ; 2014: 374526, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24701163

RESUMO

Advancement in machining technology of curved surfaces for various engineering applications is increasing. Various methodologies and computer tools have been developed by the manufacturers to improve efficiency of freeform surface machining. Selection of the right sets of cutter path strategies and appropriate cutting conditions is extremely important in ensuring high productivity rate, meeting the better quality level, and lower cutting forces. In this paper, cutting force as a new decision criterion for the best selection of tool paths on convex surfaces is presented. Therefore, this work aims at studying and analyzing different finishing strategies to assess their influence on surface texture, cutting forces, and machining time. Design and analysis of experiments are performed by means of Taguchi technique and analysis of variance. In addition, the significant parameters affecting the cutting force in each strategy are introduced. Machining strategies employed include raster, 3D-offset, radial, and spiral. The cutting parameters were feed rate, cutting speed, and step over. The experiments were carried out on low curvature convex surfaces of stainless steel 1.4903. The conclusion is that radial strategy provokes the best surface texture and the lowest cutting forces and spiral strategy signifies the worst surface texture and the highest cutting forces.


Assuntos
Desenho de Equipamento/métodos , Fenômenos Mecânicos , Desenho de Equipamento/normas , Propriedades de Superfície
6.
Proc Inst Mech Eng H ; 228(4): 330-41, 2014 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-24569922

RESUMO

Bone loss due to thermo necrosis may weaken the purchase of surgically placed screws and pins, causing them to loosen postoperatively. The heat generated during the bone drilling is proportional to cutting speed and force and may be partially dissipated by the blood and tissue fluids, and somehow carried away by the chips formed. Increasing cutting speed will reduce cutting force and machining time. Therefore, it is of interest to study the effects of the increasing cutting speed on bone drilling characteristics. In this article, the effects of the increasing cutting speed ranging from 500 up to 18,000 r/min on the thrust force and the temperature rise are studied for bovine femur bone. The results of this study reveal that the high-speed drilling of 6000-7000 r/min may effectively reduce the two parameters of maximum cortical temperature and duration of exposure at temperatures above the allowable levels, which in turn reduce the probability of thermal necrosis in the drill site. This is due to the reduction of the cutting force and the increase in the chip disposal speed. However, more increases in the drill bit rotational speed result in an increase in the amount of temperature elevation, not because of sensible change in drilling force but a considerable increase in friction among the chips, drill bit and the hole walls.


Assuntos
Osso e Ossos/fisiopatologia , Temperatura Alta/efeitos adversos , Necrose/fisiopatologia , Procedimentos Ortopédicos/efeitos adversos , Animais , Osso e Ossos/lesões , Osso e Ossos/cirurgia , Bovinos , Modelos Biológicos , Necrose/etiologia , Procedimentos Ortopédicos/instrumentação , Procedimentos Ortopédicos/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...